Bio:
Email: 524298143@qq.com
高雅君(1989—),女,大学本科,工程师,从事产品检验检测工作;524298143@qq.com
采用原子吸收光谱(AAS)法和电感耦合等离子体原子发射光谱(ICP-AES)法测定肥料中重金属元素铬的含量,从检出限、精密度和加标回收率等方面进行方法学考查。结果表明:AAS法的检出限为20 μg /L,相对标准偏差(RSD)为0.92%~1.38%,加标回收率为95.35%~95.80%;ICP-AES法的检出限为10 μg/L,RSD为0.35%~0.86%,加标回收率为96.60%~97.60%。两种方法均可准确测定肥料中重金属铬的含量。
Atomic absorption spectrometry (AAS) and inductively coupled plasma atomic emission spectrometry (ICP-AES) are employed to determine the chromium content in fertilizer. Methodological evaluations are conducted in terms of limit of detection, precision, and the spiked recovery rates. The results show that the limit of detection for AAS is 20 μg/L, with a relative standard deviation (RSD) of 0.92%-1.38% and the spiked recovery rate of 95.35%-95.80%. For ICP-AES, the limit of detection is 10 μg/L, with an RSD of 0.35%-0.86% and the spiked recovery rate of 96.60%-97.60%. Both methods can accurately determine the content of heavy metal chromium in fertilizers.
JIANG B W, LI X R, SHAO H, et al. Effects of substitution of organic manure for chemical fertilizer on phosphorus accumulation and grain yield in maize[J]. Journal of Northeast Agricultural University (English Edition), 2022, 29(3): 11-20.